Download | - View final version: Solutions for mid-rise wood construction: fire test for rainscreen wall system: Test EXTW-5: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings (PDF, 13.4 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.4224/21274565 |
---|
Author | Search for: Gibbs, E.1; Search for: Taber, B.C.1; Search for: Lougheed, G.D.1; Search for: Su, J.Z.1; Search for: Bénichou, N.1 |
---|
Affiliation | - National Research Council of Canada. Construction
|
---|
Format | Text, Technical Report |
---|
Physical description | 22 p. |
---|
Subject | fire tests; wood construction; rainscreen wall systems |
---|
Abstract | One of the tasks in the project, Wood and Wood-Hybrid Midrise Buildings, was to develop further information and data for use in developing generic exterior wall systems for use in mid-rise buildings using either lightweight wood frame or cross-laminated timber as the structural elements. This report describes a screening fire test conducted on August 22, 2012 on a rainscreen wall system. The test was based on CAN/ULC-S134-13 [3]. However, the dimensions of the test wall (2.4 m wide by 4.9 m high) were less than those required for the standard test conducted in accordance with CAN/ULC-S134. |
---|
Publication date | 2014-03-31 |
---|
Publisher | National Research Council of Canada |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | No |
---|
NPARC number | 21274565 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 57d8b68a-28b0-42f5-974d-af531b22fa2c |
---|
Record created | 2015-03-17 |
---|
Record modified | 2022-07-06 |
---|