DOI | Trouver le DOI : https://doi.org/10.1109/ICSENS.2011.6127315 |
---|
Auteur | Rechercher : Griffin, R.H.; Rechercher : Kochermin, A.; Rechercher : Tarr, N.G.; Rechercher : McIntosh, H.1; Rechercher : Ding, H.1; Rechercher : Weber, J.1; Rechercher : Falcomer, R. |
---|
Affiliation | - Conseil national de recherches du Canada. Institut des sciences des microstructures du CNRC
|
---|
Format | Texte, Article |
---|
Conférence | 10th IEEE SENSORS Conference 2011, SENSORS 2011, 28 October 2011 through 31 October 2011, Limerick |
---|
Sujet | Count rates; Radon concentrations; Radon detectors; Radon monitors; Readout Electronics; Second generation; Turn-on transients; Electrostatics; Sensors; Radon |
---|
Résumé | A second generation fast-responding passive radon detector using electrostatic concentration and enhanced readout electronics has been designed, built and tested. This detector utilizes the custom α-detecting IC called αRAM. In order to assess the response time, simulations were performed to analyze the turn-on transient of the detector. In an ambient with constant radon concentration, simulations indicate 1.44 hours will be required for the detector to reach 90% of its maximum count rate. This result is consistent with experimental findings using both first and second generation passive radon detectors. © 2011 IEEE. |
---|
Date de publication | 2011 |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21271507 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | b60c4aad-6ac6-4ba1-996d-59ccffd4a39b |
---|
Enregistrement créé | 2014-03-24 |
---|
Enregistrement modifié | 2020-04-21 |
---|