DOI | Trouver le DOI : https://doi.org/10.1109/TIM.2008.2008861 |
---|
Auteur | Rechercher : Sanchez, C. A.1; Rechercher : Wood, Barry1; Rechercher : Inglis, A.1 |
---|
Affiliation | - Conseil national de recherches du Canada. Institut des étalons nationaux de mesure du CNRC
|
---|
Format | Texte, Article |
---|
Sujet | cryogenic electronics; current comparators; resistance measurement; resistors; uperconducting devices |
---|
Résumé | We have built a cryogenic current comparator (CCC) resistance bridge for the comparison of standard resistors in the range of 1 Omega-100 kOmega. The use of fully programmable current sources allows for smooth polarity reversals, regardless of the time constant of each side of the bridge. We measured a CCC transfer function of 2.25 muA middotturn/phi0 and a noise level of 54 pA middot turn/radic(Hz) at 1 Hz, with a 1/f corner of about 0.6 Hz. Two different readout schemes were implemented and compared with good agreement. We performed a few measurements to assess the accuracy of the bridge and evaluated all the significant sources of error. The total uncertainty of the bridge is estimated to be 2.6 parts in 109 between 1 Omega and 10 kOmega. |
---|
Date de publication | 2008-12-12 |
---|
Maison d’édition | IEEE |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro du CNRC | NRC-INMS-4673 |
---|
Numéro NPARC | 8899981 |
---|