DOI | Trouver le DOI : https://doi.org/10.1109/CPEM.2014.6898613 |
---|
Auteur | Rechercher : Djokic, Branislav1 |
---|
Affiliation | - Conseil national de recherches du Canada. Science des mesures et étalons
|
---|
Format | Texte, Article |
---|
Conférence | 29th Conference on Precision Electromagnetic Measurements, CPEM 2014, 24 August 2014 through 29 August 2014 |
---|
Sujet | Ac voltage; Current comparators; Digital sampling; Measurement uncertainty; New calibration system; Power frequency; Calibration |
---|
Résumé | A new current-comparator-based dual-channel calibration system for AC voltages in the millivolt range for operation at power frequencies has been developed. The range of generated voltages is 1 mV - 100 mV. The calibration system in-phase and quadrature expanded measurement uncertainties (k=2) are estimated to be within 25·106. The traceability to SI units is established through the calibration of standard resistor, capacitor, and current comparator ratios. |
---|
Date de publication | 2014-08 |
---|
Dans | |
---|
Série | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21272931 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 72896525-6c2a-40b5-b885-d32c7cce8997 |
---|
Enregistrement créé | 2014-12-03 |
---|
Enregistrement modifié | 2020-04-22 |
---|