DOI | Trouver le DOI : https://doi.org/10.1109/CEIDP.1988.26313 |
---|
Auteur | Rechercher : Haridoss, S.; Rechercher : Crine, J.-P.; Rechercher : Bulinski, A.1; Rechercher : Densley, J.1; Rechercher : Bamji, S.1; Rechercher : Bernstein, S. S. |
---|
Affiliation | - Conseil national de recherches du Canada. Institut des étalons nationaux de mesure du CNRC
|
---|
Format | Texte, Article |
---|
Conférence | 1988 Conference on Electrical Insulation and Dielectric Phenomena, October 16-20, 1988, Ottawa, Ontario, Canada |
---|
Résumé | In order to detect oxidation in water trees, the authors performed micro-FTIR spectroscopy and oxidative induction time (OIT) measurements in many trees grown in various field-aged distribution cables. It is concluded that there is no definitive evidence that oxidation affects water-tree initiation in field-aged cross-linked polyethylene cables. It is found, in fact, that trees may be less oxidized than untreed insulations. It seems that the reduced OIT values of aged cables correspond to reduced antioxidant content. |
---|
Date de publication | 1988 |
---|
Dans | |
---|
Langue | anglais |
---|
Numéro du CNRC | NRC-INMS-1709 |
---|
Numéro NPARC | 8897087 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 6a3702d5-220f-4570-90e6-7ee06d829d65 |
---|
Enregistrement créé | 2009-04-22 |
---|
Enregistrement modifié | 2020-03-17 |
---|