DOI | Trouver le DOI : https://doi.org/10.1109/CPEM.2012.6250681 |
---|
Auteur | Rechercher : Michaud, Alain1 |
---|
Affiliation | - Conseil national de recherches du Canada. Science des mesures et étalons
|
---|
Format | Texte, Article |
---|
Conférence | CPEM 2012, 2012 Conference on Precision Electromagnetic Measurements, July 1-6, 2012, Washington, DC, United States |
---|
Sujet | network parameters; S-parameters; TRL fixture calibration standard; axisymmetric model; finite element analysis |
---|
Résumé | We evaluate the RF network scattering parameters (S-parameters) of the calibration standards for the coaxial transmission lines. Those standards include: single ended open/shorts, step discontinuities in inner/outer conductors, tapers, and mismatch airlines. We use either an analytical function when the geometry is simple, or finite elements analysis for the more elaborate geometry. Whenever possible, we compare the analytic, numerical and experimental results. |
---|
Date de publication | 2012 |
---|
Maison d’édition | IEEE |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21269094 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 5a1ddba5-24f5-4347-a317-81080f86a46d |
---|
Enregistrement créé | 2013-12-05 |
---|
Enregistrement modifié | 2024-03-07 |
---|