DOI | Trouver le DOI : https://doi.org/10.1109/CPEM.2012.6250697 |
---|
Auteur | Rechercher : Van den brom, Helko E.; Rechercher : Jol, Leendert; Rechercher : Rietveld, Gert; Rechercher : So, Eddy1 |
---|
Affiliation | - Conseil national de recherches du Canada. Science des mesures et étalons
|
---|
Format | Texte, Article |
---|
Conférence | CPEM 2012, 2012 Conference on Precision Electromagnetic Measurements, July 1-6, 2012, Washington, DC, United States |
---|
Sujet | current transformers; alternating current; current measurement; current ratio; digital sampling |
---|
Résumé | A measurement setup is developed for the accurate ratio measurement of AC current transformers (CTs) for primary currents up to 5 kA. A unique property of the system is the use of digitizers for sampling of the secondary current signals and step-down transformers with a large number of current ratios. This allows for accurate comparison of CTs even when their nominal ratios are not equal. |
---|
Date de publication | 2012 |
---|
Maison d’édition | IEEE |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21269100 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 4b2a3032-00ce-43d1-9e8c-029749afb321 |
---|
Enregistrement créé | 2013-12-05 |
---|
Enregistrement modifié | 2024-03-07 |
---|