DOI | Trouver le DOI : https://doi.org/10.1109/CPEM.2012.6250981 |
---|
Auteur | Rechercher : So, Eddy1; Rechercher : Arseneau, Rejean1; Rechercher : Tang, Yi-hua; Rechercher : Stenbakken, Gerard; Rechercher : Nelson, Tom |
---|
Affiliation | - Conseil national de recherches du Canada. Science des mesures et étalons
|
---|
Format | Texte, Article |
---|
Conférence | CPEM 2012, 2012 Conference on Precision Electromagnetic Measurements, July 1-6, 2012, Washington, DC, United States |
---|
Sujet | current-comparator-based system; high voltage PMU; on-site calibrations |
---|
Résumé | The development of a current-comparator-based system for on-site calibrations of high voltage phasor measurement unit systems will be presented. Measurement can be made under actual power system operating conditions with voltages up to 100 kV line-to-ground and currents up to 2000 A at 50 Hz or 60 Hz. |
---|
Date de publication | 2012 |
---|
Maison d’édition | IEEE |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21269115 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 30f6f983-40f4-4173-b88f-9623940d6d0d |
---|
Enregistrement créé | 2013-12-06 |
---|
Enregistrement modifié | 2024-03-07 |
---|