DOI | Trouver le DOI : https://doi.org/10.1109/CPEM.2012.6250875 |
---|
Auteur | Rechercher : So, Eddy1; Rechercher : Arseneau, Rejean1; Rechercher : Angelo, Dave1 |
---|
Affiliation | - Conseil national de recherches du Canada. Science des mesures et étalons
|
---|
Format | Texte, Article |
---|
Conférence | CPEM 2012, 2012 Conference on Precision Electromagnetic Measurements, July 1-6, 2012, Washington, DC, United States |
---|
Sujet | current-comparator; power bridge; power standard; uncertainty |
---|
Résumé | An improved power standard derived from a current comparator power bridge for calibrating active/reactive power and energy meters under sinusoidal conditions is described. Measurements can be made at any power factor from zero lag through unity to zero lead, positive or negative power, at 120 V, 5 A, and 50 or 60 Hz. The improved power standard has an estimated basic uncertainty of 2.5 μW/VA at k = 1. |
---|
Date de publication | 2012 |
---|
Maison d’édition | IEEE |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21269103 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 049d3626-4f54-41f3-b659-79d878f71fae |
---|
Enregistrement créé | 2013-12-05 |
---|