DOI | Resolve DOI: https://doi.org/10.1021/bp050225j |
---|
Author | Search for: Tartakovsky, B.1; Search for: Guiot, S. R.1 |
---|
Affiliation | - National Research Council of Canada. NRC Biotechnology Research Institute
|
---|
Format | Text, Article |
---|
Subject | Bioelectric Energy Sources; Bioreactors; Electrodes; Hydrogen Peroxide; Oxygen |
---|
Abstract | In this study, a two-compartment continuous flow microbial fuel cell (MFC) reactor was used to compare the efficiencies of cathode oxygenation by air and by hydrogen peroxide. The MFC reactor had neither a proton-selective membrane nor an electron transfer mediator. At startup, the cathodic compartment was continuously aerated and the anodic compartment was fed with a glucose solution. An increase of electrical power generation from 0.008 to 7.2 mW m−2 of anode surface with a steady-state potential of 215–225 mV was observed within a period of 12 days. The performance of the air-oxygenated MFC reactor progressively declined over time because of biofilm proliferation in the cathodic compartment. Oxygenation of the cathodic compartment using 300 mL d−1 of 0.3% hydrogen peroxide solution resulted in a power density of up to 22 mW m−2 (68.2 mA m−2) of anode surface at a potential of 340–350 mV. The use of H2O2 for oxygenation was found to improve the long-term stability of the MFC reactor. |
---|
Publication date | 2006 |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 12327670 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | e9392a27-acf6-4e0c-a5af-46accddb2408 |
---|
Record created | 2009-09-10 |
---|
Record modified | 2020-04-22 |
---|