Download | - View accepted manuscript: Accurate measurement of microwave power in the IEC: R-70 (WR-138) waveguide transmission line (PDF, 551 KiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.1109/CPEM.2014.6898604 |
---|
Author | Search for: Michaud, Alain1 |
---|
Affiliation | - National Research Council of Canada. Measurement Science and Standards
|
---|
Format | Text, Article |
---|
Conference | 29th Conference on Precision Electromagnetic Measurements, CPEM 2014, 24 August 2014 through 29 August 2014 |
---|
Subject | Accurate measurement; Microcalorimeter; Microwave power; Rabi oscillations; Radio frequency power; Waveguide transmission line; Laser cooling |
---|
Abstract | We compare the accuracy of different techniques to measure guided RF power at 6.83 GHz. The transmission line is a standard rectangular metallic waveguide IEC: R-70 (WR-138). We used three calculable standards including a waveguide calorimeter, a coaxial calorimeter, and an atomic (quantum based) power meter based on laser cooled rubidium atoms. |
---|
Publication date | 2014-08 |
---|
In | |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 21272907 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | d2577925-4037-4066-94a8-06870f0c58c7 |
---|
Record created | 2014-12-03 |
---|
Record modified | 2020-06-04 |
---|