Download | - View accepted manuscript: Correction of systematic errors due to the voltage leads in an AC Josephson Voltage Standard (PDF, 742 KiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.1109/TIM.2008.2008086 |
---|
Author | Search for: Filipski, Piotr S.1; Search for: Kinard, Joseph R.; Search for: Lipe, Thomas E.; Search for: Tang, Yi-Hua; Search for: Benz, Samuel P. |
---|
Affiliation | - National Research Council of Canada
|
---|
Format | Text, Article |
---|
Abstract | The National Institute of Standards and Technology (NIST) has recently reported the first application of a quantum ac Josephson voltage standard for the calibration of thermal transfer standards in the 1- to 10-kHz frequency range. This paper describes preliminary work on extending its frequency calibration range up to 100 kHz by correcting the systematic errors due to voltage leads. A ground loop created by the dc blocks, which is a previously unaccounted source of high-frequency systematic error, has been identified, and its effects are partially mitigated. |
---|
Publication date | 2009-04 |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 18116653 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 848bde35-0377-4db9-9e4e-2c488274e53a |
---|
Record created | 2012-03-09 |
---|
Record modified | 2020-04-16 |
---|